Burner and nozzle specications
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*
power power 1/100 1/100 (g/h) power 1/100 (l/h)
kW kW kW
(p.c.s.*) (p.c.s.*) (p.c.s.*)
(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
Reduced Fast (RR) 100 0,70 2,60 39 80 189 186 2,60 110 (Y) 248
Semi Fast (S) 75 0,40 1,90 28 70 138 136 1,90 106 181
Auxiliary (A) 55 0,40 1,00 28 50 73 71 1,00 79 95
Triple Crown (TC) 130 1,50 3,30 61 91 240 236 3,60 145 (H1) 343
Supply Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m
3
PFS750T/HA
EHP 750 T /HA
RR
TC
S
S
A
! The hob can only be installed above built-in ovens with a cooling ventilation system.